NZ electricity contracts and derivatives.
A guide for analysts and new traders: what each product does, why it exists in New Zealand, and where the risks sit.
Purpose of this primer
New Zealand is electrifying at pace. More generation will need to be built and connected over the next 15 years than in the previous 40, and much of it will be wind and solar. Every one of those projects depends on contracts that turn a volatile spot price into revenue a lender can rely on.
This primer explains those contracts in plain terms. It is written for analysts and new traders who need to understand how each product works, why it exists in the New Zealand market, and where the risks sit. Each section can be read on its own. The section on certificates connects these products to renewable energy certificates and granular REGOs.
The spot market: why these contracts exist
Every contract in this document exists to manage one thing: volatile spot prices in the New Zealand wholesale electricity market.
- One pool. Almost all electricity is bought and sold through the wholesale spot market. Generators offer into it. Retailers and large direct consumers buy from it.
- Half-hourly, nodal prices. Prices are set for every half-hour trading period at hundreds of grid nodes. Otahuhu (Auckland) and Benmore (lower South Island) are the main reference nodes.
- Hydro first, but fuel-constrained. Hydro still supplies most of New Zealand’s electricity, so prices rise sharply in dry years and on cold, still winter evenings, and can fall close to zero when lakes are full and the wind is blowing. But hydro is backed up by gas- and coal-fired plant, and domestic gas supply is falling faster than expected. Gas now matters almost as much as rainfall.
- Gentailers. The large generators also own retailers, so much hedging happens inside vertically integrated businesses. Independent retailers and large users rely on the contract market for cover.
When the fuel mix is stressed
The system copes well when only one thing goes wrong. It creaks when several go wrong together, as they did in winter 2024:
- Low hydro. Lake storage fell steadily from April and reached a six-year low in early August.
- Less gas. Gas supply dropped sharply, so gas-fired plant could not run flat out when it was needed most.
- No wind, high demand. Cold snaps lifted demand just as wind generation fell away.
- Low coal. The coal stockpile at Huntly, the backstop for gas, ran down quickly.
Spot prices rose from around $300/MWh in July to over $800/MWh in early August, with some half-hours above $1,100/MWh at Otahuhu. Pressure eased only when the country’s largest gas user paused production and sold its gas to generators, and rain and wind returned.
The irony is hard to miss. In a decade focused on decarbonisation, coal burned at Huntly has been the backstop that kept the system running through tight winters, and that role is now formalised in a ten-year coal reserve. Until enough storage, flexible demand and other firm low-carbon supply are built, dry-year security still leans on fossil fuels.
Domestic gas production has roughly halved since 2016 and is forecast to keep falling, with reserves at a record low and the Māui field due to close at the end of 2026 (see section 10). That has brought more fuel-linked contracts alongside electricity hedges: gas swaps and gas options between producers, large users and generators; deals where a large gas user pauses production and releases its gas to power stations, with the price linked to electricity prices; and long-dated firming options on thermal capacity, such as ten-year options over Huntly’s coal- and gas-fired units backed by a shared coal reserve (see section 09). Watch gas and coal stocks as closely as lake levels.
The useful way to think about it: physical power always flows through the spot market. Contracts sit on top as financial payments that change what each party effectively pays or receives.
How that half-hour price is actually set, minute by minute, is covered in section 03.
Real-time pricing: how the spot price is made
Every contract in this primer settles against one number: the spot price for each half-hour trading period at a node. Since 1 November 2022, that price has been set in real time, from the prices struck while the system is actually being run.
From offers to a price
- Offers and bids. Generators offer their output in price bands, and some large users and batteries bid to reduce demand or supply power.
- Dispatch. Every few minutes the system operator solves for the cheapest way to meet demand safely, including reserves and transmission limits, and sends dispatch instructions.
- Dispatch prices. Each dispatch run sets a price at every node, roughly every five minutes.
- The half-hour price. At the end of the trading period, the dispatch prices are averaged, weighted by how long each one applied, and published straight away. Before 2022 the price was worked out the next day and took about two days to confirm.
The trading period
What it means for contracts
Illustrative. The six intervals are treated as five minutes each; in practice they vary in length, so the average is time-weighted.
The prices you will see
Before and during the period
- Forecast prices
- From schedules run in the days and hours ahead, using the latest offers and demand forecasts. Good for planning, but they move as conditions change.
- Dispatch prices
- Struck each time the system operator issues dispatch instructions, at every node. These are the live prices batteries, flexible demand and traders watch.
After the period
- Interim price
- The time-weighted average of the dispatch prices, published as soon as the trading period ends.
- Final price
- The interim price, confirmed once a short window for pricing error claims has passed. Final prices are what the spot market, and every contract in this primer, settles on.
Scarcity pricing
When there is not enough generation or reserve to run the system securely, prices are set automatically at scarcity values rather than by the last offer. They signal a genuine shortage, and they reward anyone who can reduce demand or supply more power at that moment.
- Energy scarcity (since 17 April 2025): $21,000/MWh for the first 5% of demand that cannot be met, $31,000/MWh for the next 15%, and $50,000/MWh for the rest.
- Reserve scarcity: $7,000/MWh for fast instantaneous reserve and $6,500/MWh for sustained instantaneous reserve. A reserve shortfall can lift energy prices too.
- Rare in practice. Energy scarcity pricing had not occurred in real-time or final prices when the values were last reviewed, and reserve scarcity only briefly. The values are reviewed at least every five years.
How it connects to contract prices
- Everything settles on the half-hour final price. CFDs, futures, caps and floors all compare their strike with the final price for each trading period, so a five-minute spike reaches every contract through the half-hour average.
- Caps pay on the average, not the peak. A five-minute price of $1,950 inside a $450 half-hour does not trigger a $500 cap. Short spikes are diluted; sustained ones are not.
- Nodes still matter. Dispatch prices are set at every node, so the price differences that FTRs and basis risk deal with (sections 12 and 15) are formed the same way.
- Flexibility earns the five-minute price. Batteries, demand response and fast plant can see prices live and act within the half-hour. Contracts cover the average; flexibility captures the shape inside it.
- Futures and forward prices (section 06) are expectations of the average of these final prices over a month or quarter, including the occasional spike.
Households and businesses
Most households and small businesses do not pay the spot price. Their retailer buys at spot or through contracts and sells to them on fixed, time-of-use or, occasionally, spot-linked plans. The Authority is pushing retailers to offer more time-varying plans, so that more consumers can benefit from shifting use away from expensive periods.
The final price is known as each trading period ends, so there are no next-day surprises. Watch dispatch prices during the period: in a morning ramp they often climb steadily within each half-hour, giving a saw-tooth pattern, and the half-hour average can sit well below the last five-minute price. When scarcity pricing appears, it is a signal that the system is short, not a pricing error.
Power purchase agreements (PPA)
A PPA is a long-term agreement, usually 10 to 20 years, between a generator and a buyer to trade electricity at a pre-agreed price.
Why each side signs
A new wind or solar farm needs debt finance. Lenders lend against contracted revenue, not spot prices. The PPA is what makes the project bankable.
A large industrial or corporate gets long-term price certainty and can claim the renewable attributes (REGOs) for emissions reporting.
Key terms to check
| Term | What it means |
|---|---|
| Price | Fixed $/MWh, often escalating with CPI |
| Volume and shape | Generation following (pay-as-produced: buyer takes whatever the plant generates), load following (volume tracks the buyer’s consumption), baseload (flat MWh every half-hour) or a shaped profile |
| Term | Length of the deal and start date, often tied to plant commissioning |
| Reference node | The grid location where the settlement price is measured |
| Certificates | Who receives the REGOs and how they are transferred |
| Credit support | Guarantees or collateral if a party fails |
| Change in law | What happens if market rules or regulation change |
Generation following and load following
The biggest choice in a PPA is whose volume the contract tracks. That decides who carries the risk when generation and consumption do not line up.
| Generation following | Load following | |
|---|---|---|
| Contract volume | Whatever the plant generates in each half-hour. Also called pay-as-produced | Whatever the buyer consumes in each half-hour |
| Who carries volume and shape risk | The buyer. Over-hedged when the plant runs hard, back on spot when it does not | The seller, who must cover the gap between plant output and the buyer’s load |
| Typical seller | A single wind or solar farm | A retailer or gentailer with a portfolio to firm against |
| Price | Usually the lowest $/MWh | Higher. The premium is the cost of firming |
| Why it is chosen | Gives the generator revenue on every MWh, so the project is easy to finance | Gives the buyer close to a fixed electricity cost |
| Certificates | Match the plant’s output, not the buyer’s load. Hourly matching shows the uncovered hours | Depends on the seller’s sources. Check the contract says which generation backs the supply |
In short, generation following suits the generator and load following suits the buyer. The price difference between them is the cost of firming. A sleeved PPA often joins the two: the retailer takes the generator’s pay-as-produced output and gives the customer a load-following supply.
Physical and financial PPAs in New Zealand
Because power flows through the spot market, most New Zealand PPAs take one of two forms:
- Sleeved: A retailer sits in the middle and passes the PPA price through to the buyer’s bill.
- Financial (virtual): Both parties keep trading at spot and settle a payment between themselves. This is a Contract for Difference, covered in the next section.
In short, the PPA is the commercial deal. The CFD is usually the financial mechanism inside it.
Contracts for difference (CFDs)
A CFD fixes a price, the strike. Each half-hour, the parties settle the difference between the strike and spot, multiplied by the contract volume. In New Zealand this is often simply called a swap or a hedge.
- When spot is above the strike, the seller (generator) pays the buyer the difference.
- When spot is below the strike, the buyer pays the seller the difference.
Neither party leaves the spot market. The CFD is a side payment, and the net result is that both effectively trade at the strike.
Worked example
Strike $150/MWh, 10 MWh in one trading period.
| Spot = $250/MWh | Spot = $80/MWh | |
|---|---|---|
| Buyer pays at spot | $2,500 | $800 |
| CFD settlement to buyer | +$1,000 | −$700 |
| Buyer net cost | $1,500 | $1,500 |
| Generator earns at spot | $2,500 | $800 |
| CFD settlement to generator | −$1,000 | +$700 |
| Generator net revenue | $1,500 | $1,500 |
Both sides land on $150 × 10 MWh = $1,500, whatever spot does. Each side gives up some upside to remove the downside.
Buyer
Generator
Strike $150/MWh, 10 MWh. Whatever the spot price, both sides net $1,500.
A CFD works like an interest rate swap on a mortgage. You still pay the bank the floating rate, but the swap tops you up or takes back the difference, so you end up paying the fixed rate.
Common shapes
- Baseload: the same MWh every trading period, around the clock.
- Peak: only in defined peak periods, typically weekday daytime and evening.
- Pay-as-produced: volume follows a specific plant’s output. Typical of renewable PPAs.
- Load-following: volume follows the buyer’s demand. This is the hardest for a seller to cover, so it is priced higher.
- Super-peak: the morning (7:00 to 10:30 am) and evening (5:00 to 9:00 pm) peaks, every day. A standardised super-peak contract has traded since 2025 and is now market made (section 07).
Fixed price variable volume (FPVV) supply
Most New Zealand businesses never sign a CFD. They buy on a fixed price variable volume contract from a retailer: agreed rates per kWh for one to three years, often varying by season and time of day, charged on whatever they actually use. The alternative is spot price pass-through, where the customer pays spot plus a margin and manages the price risk themselves.
Under FPVV the retailer carries the risk. It buys at a spot price that changes every half-hour and sells at the fixed rate, so it is exposed both to price and to the customer using more or less than expected. That risk is priced into the rate as a premium.
| FPVV | CFD | PPA | |
|---|---|---|---|
| What it is | Retail supply contract, delivered to the meter | Financial hedge settled against spot | Long-term deal linked to a specific generator |
| Price | Fixed | Fixed (the strike) | Fixed, often escalating with CPI |
| Volume | Whatever the customer uses | A set MW for each trading period | What the plant generates, or what the buyer uses if load following |
| Typical term | 1 to 3 years | Months to a few years | 10 to 20 years |
| Who carries volume risk | The retailer | The party whose actual volume differs from the hedge | The buyer if generation following, the seller if load following |
The three fit together:
- Retailers hedge FPVV with CFDs. A retailer covers its expected FPVV sales with CFDs and futures. CFDs are fixed volume and customer usage is not, so the hedge never fits perfectly. The gap is the volume risk the retailer is paid to carry.
- Large users can build their own. Buying at spot and holding CFDs for most of the expected load is usually cheaper than FPVV, but usage above or below the hedged volume is exposed to spot.
- A load-following PPA is a long-term FPVV backed by named generation. A sleeved PPA often reaches the customer this way: the retailer takes the generator’s pay-as-produced output and bills a fixed price on whatever the customer uses.
- A generation-following PPA does not replace supply. The buyer still needs FPVV or spot supply for its actual load. The PPA sits alongside as a hedge.
Futures and the forward curve
A futures contract is a standardised CFD traded on an exchange. In New Zealand, electricity futures trade on the ASX and settle against the average spot price at Otahuhu or Benmore over a month or quarter.
How futures differ from an OTC CFD
| Feature | ASX futures | OTC CFD |
|---|---|---|
| Terms | Standard: fixed node, period and volume | Negotiated: any node, shape or term |
| Counterparty | Clearing house | The other party directly |
| Credit | Daily margining | Credit limits, guarantees, collateral |
| Price visibility | Public | Private |
Worked example: one contract over 24 months
A retailer wants to fix the cost of supplying its customers next winter but one. Twenty-four months before delivery it buys one Otahuhu baseload futures contract for the third quarter (July to September). A generator, wanting to lock in revenue for the same period, sells it. Both trade at $165/MWh.
The contract covers 1 MW in every hour of the quarter: 92 days × 24 hours = 2,208 MWh. So every $1/MWh the price moves is worth $2,208 to each side, in opposite directions. In the table, the retailer and generator columns show the running total of margin each side has received (+) or paid (−).
Retailer (bought)
Generator (sold)
Illustrative prices and events. Margin is paid in cash every day; the locked-in price never moves.
| When | Price | What happened | Retailer | Generator |
|---|---|---|---|---|
| 24 months before | $165 | Trade. The retailer buys and the generator sells one Q3 contract at $165/MWh. Both post initial margin with the clearing house. | $0 | $0 |
| 18 months before | $174 | Gas outlook cut. Gas producers lower their deliverability forecasts. Thermal fuel is expected to cost more, so winter prices are expected to be higher. | +$19,872 | −$19,872 |
| 12 months before | $152 | More supply, less demand. A large wind farm and a grid-scale battery are confirmed on schedule, and a big industrial user announces a plant closure. | −$28,704 | +$28,704 |
| 6 months before | $188 | Dry summer. A dry summer leaves hydro storage below average heading into autumn. | +$50,784 | −$50,784 |
| 3 months before | $236 | Low lakes. Storage is about 70% of average and snowpack is low. Retailers rush to hedge winter, and few sellers want to. | +$156,768 | −$156,768 |
| 1 month before | $205 | June rain. Heavy rain lifts the lakes and some of the dry-year premium comes out of the price. | +$88,320 | −$88,320 |
| End of the quarter | $191 | Final settlement. The contract settles at the average Otahuhu spot price over July to September: $191/MWh. | +$57,408 | −$57,408 |
What the example shows
- The outcome is fixed on the day of the trade. Over the life of the contract the retailer receives ($191 − $165) × 2,208 = $57,408 and the generator pays it. The retailer pays $191 at spot for its customers’ power and gets $26 back, so it pays $165. The generator earns $191 at spot and pays $26 away, so it also nets $165. The path in between makes no difference to that result.
- The path decides the cash flow. Gains and losses are paid in cash every day through variation margin. Twelve months out, the retailer had paid out $28,704 on a hedge that ended up in its favour. Three months out, the generator had paid out $156,768 on one contract, while the power it would generate was worth more by the same amount. A business holding many contracts needs the cash to meet these calls, or it may be forced to close its hedges at the worst time.
- Mark-to-market losses are not real losses on a good hedge. The generator’s futures position showed a large loss in the dry spell, but its future generation had risen in value by the same amount. Judging a hedge on its futures position alone is a common mistake.
- Either side can exit early. Selling the contract back at three months out, for $236, would have locked in $156,768 for the retailer, but left it unhedged for winter. Closing a hedge is a new decision, not a free profit.
- The price converges. As the quarter runs, more of the average spot price is already known, so the futures price closes in on where it finally settles.
- The hedge is only as good as the fit. It works exactly only if the retailer’s customers use a flat 1 MW at Otahuhu. Real load has a shape and a location, which leaves volume and basis risk (see section 15).
Contracts 24 months away trade less often than the next few quarters, and bid-offer spreads are wider. Much of the pricing that far out comes from market makers, who are required to post buy and sell prices on the ASX for a set period ahead. See section 07.
Moving between the two: exchange for physical (EFP)
A CFD and a futures contract are the same hedge in two forms: one bilateral, one cleared. An exchange for physical converts one into the other. It is an off-market transaction in which two parties swap an OTC position, such as a swap, swaption or cap, for the matching ASX futures or options position.
- Agree: the two parties negotiate the price and volume between themselves, away from the trading screen.
- Register: the trade is registered with the exchange through an ASX 24 participant.
- Result: the OTC contract falls away and each party holds a cleared position, facing the clearing house instead of each other.
It removes counterparty credit risk on a deal that was negotiated privately, and lets large or tailored volumes move on-exchange without working them through a thin order book. It also runs in reverse, from futures back to OTC.
Exchange fees, plus initial and daily margin. Margin ties up cash, which is why some participants choose to stay OTC.
An EFP is not the same as a block trade. A block trade is also negotiated off-screen, but it is a straight futures trade with no OTC leg.
The forward curve
Futures prices for each future quarter, taken together, form the forward curve. It is the market’s current price for electricity delivered in each future period. It is used to:
- price new OTC deals and PPAs;
- mark existing contracts to market each day;
- signal market expectations. A steep winter premium signals concern about hydro storage or gas supply.
If you bought at $150 and the curve for that period is now $180, the contract is worth $30/MWh × remaining volume to you, before discounting.
A forward curve is a price, not a forecast. It includes a risk premium, and in New Zealand that premium is largest in the winter periods.
How the curve signals price to the market
Because futures trade on a public exchange, the curve gives everyone the same reference price for every quarter ahead. That makes it a signal as well as a hedge.
- Retail and contract prices. Retailers price fixed price variable volume offers and OTC CFDs off the curve, and PPA negotiations start from its long-dated end.
- Investment. When long-dated prices sit above the cost of new wind, solar, geothermal or batteries, the curve says new supply will pay. Developers and lenders use it to test business cases. When prices fall below new-build cost, the signal is that supply is adequate for now.
- Security of supply. A sharp rise in next winter’s prices tells hydro generators to conserve water, thermal generators to secure fuel, and large users to line up demand response or more hedging. The signal arrives months before any shortage.
- The value of flexibility. The gap between winter and summer prices, and between peak and baseload, is what storage, batteries and flexible demand can earn by shifting energy in time.
- Location. The gap between Otahuhu and Benmore prices reflects the cost and risk of moving power north, including HVDC and grid constraints.
The signal is only as good as the trading behind it. The near quarters trade most. Further out, prices depend more on market makers: New Zealand’s largest generator-retailers and a commercial market maker contracted by the Electricity Authority post buy and sell prices on the ASX. From 1 March 2027, required market making on quarterly baseload contracts extends from three to five years ahead, which will lengthen the reliable part of the curve. How market making works is covered in section 07.
What goes into a futures price
A trader pricing a future quarter is estimating the average spot price for that period, then adding a premium for the risk of being wrong. The main inputs:
| Input | What traders watch | Effect on price |
|---|---|---|
| Hydro storage and inflows | Lake levels against the historical average, snowpack, inflow forecasts, El Niño and La Niña outlooks | Low storage lifts winter prices sharply. Full lakes push them down |
| Thermal fuel | Gas field deliverability and decline, contracted gas, coal stocks at Huntly, LNG import options | Scarcer or dearer fuel raises the cost of the plant that sets dry-year and peak prices |
| Carbon | NZU price | Adds to thermal generation’s cost, so it feeds into prices whenever thermal plant sets the price |
| New generation | Wind, solar, geothermal and battery projects, and whether they commission on time | More supply lowers later-dated prices. Delays push them back up |
| Outages | Planned maintenance of large plant and the grid, HVDC availability | Less available capacity raises prices, especially at the affected node |
| Large industrial demand | The contracts and plans of the biggest users, including the Tiwai Point aluminium smelter | A closure or cutback removes a large block of demand and lowers prices |
| Electrification and growth | Process heat conversion, electric vehicles, data centres, population and economic growth | Steady upward pressure on later years |
| Weather | Cold winters, and calm or dry spells | Raises winter and peak demand, and cuts wind and hydro output |
| Risk premium | How much buyers will pay to remove spot risk, and how much sellers want to take it on | Usually lifts futures above expected spot, most in winter |
| Positions and liquidity | Who still needs to hedge, market maker spreads, recent trades | Short-term moves when many buyers or sellers act at once |
| Rules and policy | Electricity Authority Code changes and government energy policy | Can shift the whole curve |
Hydro generators offer their water at what it may be worth later, its water value. When lakes are low, water is worth more, hydro offers rise, and futures follow. In January 2026, for example, the Electricity Authority reported Otahuhu futures for the first quarter of 2026 falling by $67/MWh in a single month, as hydro storage and inflows came in above average.
Futures can also be wrong for long periods. A 2025 study for the Electricity Authority found that long-dated New Zealand contracts have generally been priced below the spot prices that eventually arrived. The curve is the best public price available, not a guarantee.
Market making: keeping the futures market open
A futures market only works if there is someone to trade with. A market maker agrees to post a price to buy (the bid) and a price to sell (the offer) at the same time, for a set volume, so anyone who wants to hedge can do it straight away.
Why market makers exist
- Buyers and sellers rarely arrive together. A retailer may want to hedge next winter today. The generator that would sell to it may not trade until next month. Without a standing price, the first one has to wait, or pay up.
- The market is small and concentrated. The largest generator-retailers (gentailers) hedge much of their risk inside their own businesses, so they have less reason to trade. Independent retailers, large users and new generators depend on the market being open.
- The forward curve needs trades. Section 06 showed the curve is used to price PPAs, retail offers and new investment. A price nobody can trade at is not much of a signal.
- Confidence. If you know you can get out of a position at a fair price, you are more willing to take one on. Liquidity attracts more liquidity.
Market making has supported New Zealand electricity futures since they started trading on the ASX in 2010. It is now a requirement in the Electricity Industry Participation Code.
What a market maker does
In each market-making session, a market maker must:
- Quote both sides. A bid and an offer for each required contract, at the same time (a two-way price).
- Keep the gap tight. The offer can be no more than a set percentage above the bid: the maximum bid-ask spread.
- Show real size. At least a minimum volume on each side, so a meaningful hedge can be done.
- Keep quoting. Update prices as news arrives, and refresh quotes after a trade until the required volume has traded.
If a buyer and a seller both trade with it, the market maker earns the spread without holding a position. More often it is left holding one side: it has bought, and nobody has sold to it yet. That position is exposed to the next price move, which in a dry spell can be far bigger than the spread. Gentailer market makers can lean on their own generation and customers to absorb positions, and all market makers manage risk by moving their quotes and trading out.
Your quote
1 MW of a quarter (2,208 MWh)
Illustrative. The spread here is measured against the mid price. A quarter of baseload is 2,208 MWh for each MW.
How it works in New Zealand
The Electricity Authority sets the rules for two products. They are reviewed from time to time, so check the Authority’s website for the current settings.
Baseload futures (ASX)
- Product
- Monthly and quarterly baseload futures at Otahuhu and Benmore
- Who quotes
- The four largest gentailers, plus an independent commercial market maker contracted by the Authority (about a fifth of the volume)
- Where and when
- On the ASX, in a daily session from 3:30 to 4:00 pm, quoting for at least 25 minutes
- Maximum spread
- 3%
- Volume
- 12 MW per contract in total, shared between the market makers
- How far ahead
- Quarters up to three years ahead. From 1 March 2027, five years, with 8 MW for years three to five
- Required since
- Market made since 2010; now a Code requirement
Super-peak contracts
- Product
- A standardised CFD for 7:00 to 10:30 am and 5:00 to 9:00 pm every day, at Otahuhu and Benmore
- Who quotes
- The same regulated gentailers
- Where and when
- On an over-the-counter platform chosen by an industry panel, in fortnightly auctions (Tuesdays, 10:00 to 10:30 am)
- Maximum spread
- 5%, or $2/MWh if greater
- Volume
- 6 MW per contract in total
- How far ahead
- Monthly contracts for the next few months, then quarters
- Required since
- 31 July 2026 (the contract has traded since January 2025)
A market maker’s required volume falls as it trades. Heavy one-way demand can use up what it must offer in a session, and then the remaining quotes are voluntary.
When markets get stressed
Market makers are most needed when prices are moving fast, and that is exactly when quoting is riskiest. A dry spell can move winter futures by more than $50/MWh in a few weeks, many times a 3% spread.
- Stepping back. Market makers can stop quoting in limited, defined circumstances. When several step back at once, spreads can widen sharply and depth disappears.
- Temporary relief in 2024. During the dry winter of 2024 the Authority made urgent changes that let spreads widen from 3% to 5% on contracts priced above $500/MWh. It let them expire in 2025, judging that existing tools were enough.
- Spreads carry information. A wide spread tells the market that risk is high and market makers are near their limits.
The debate
- Who carries the cost. Regulated market making uses the gentailers’ capital and appetite for risk. They point to the cost in stressed markets. Independent participants point to the hedges they could not otherwise get.
- How much is enough. Volume and spread settings trade depth against risk. The 2026 review extended the curve to five years but cut volumes for the later years, and submitters disagreed on whether four- and five-year contracts are needed.
- An independent view. Alongside the gentailers, the Authority contracts a commercial market maker, funded through the Electricity Industry Levy, to add a view of prices from outside the large generators.
- Confidence in prices. Some participants have questioned whether prices set mainly by the largest generators are fair. The Authority publishes market maker performance and spread data on its EMI website.
The market-making session is when firm two-way prices are guaranteed to be on screen. Outside it, spreads can be wider and depth thinner. Check depth as well as price: the best bid may only be good for a small volume. When spreads blow out, market makers are usually near their limits, and that is information in itself.
Options: caps, floors and collars
An option is a one-way CFD. It pays only when spot moves against the holder, and the holder pays an up-front premium for that protection.
| Product | Who buys it | Pays out when | Holder keeps |
|---|---|---|---|
| Cap | Buyer of power (retailer, large user) | Spot > strike | The benefit of low prices |
| Floor | Seller of power (generator) | Spot < strike | The benefit of high prices |
| Collar | Either side | Spot outside a band | Exposure inside the band |
A retailer buys a $300/MWh cap for 10 MWh. Spot reaches $800, so the cap pays ($800 − $300) × 10 = $5,000. If spot stays at $120, the cap pays nothing and the retailer has paid only the premium. It works like insurance: the worst-case cost is the strike plus the premium.
Buy a cap and sell a floor together. The premium earned on the floor offsets the cost of the cap, often to near zero (a zero-cost collar). The price is held inside a band rather than at a single level.
What drives option premiums
- Distance to strike: the further out of the money, the cheaper.
- Volatility: the more spot moves, the more expensive. New Zealand winter volatility makes winter caps expensive.
- Time: longer cover costs more.
- Settlement basis: an option settled on each half-hour has more payout events, so it is worth more than one settled on a monthly average.
Swaptions and dry-year cover
A swaption is an option to enter a swap (CFD) at an agreed strike for a defined future period. The holder exercises it only if they need it. In New Zealand it is the main contract for dry-year and firming cover.
How it works
- The buyer pays a premium, often an annual or monthly fee, for the right to call on a CFD.
- A trigger is agreed. Usually the buyer gives notice ahead of a period. Sometimes the trigger is linked to hydro storage or spot price levels.
- If called, a CFD at the strike runs for that period. If not, nothing happens beyond the premium.
Why New Zealand needs it
In a dry year, hydro storage falls and spot prices can stay high for weeks or months, and a gas shortfall at the same time makes it worse. Thermal plant (gas and coal) must be held ready for those years, but may run very little in wet ones. A swaption pays the plant owner to stay available. It also gives retailers a ceiling on their exposure when it matters most.
Example: Huntly firming options. In 2025 the largest generator-retailers agreed ten-year firming options over capacity at Huntly’s coal- and gas-fired units. They are structured as swaptions, and backed by a jointly funded coal reserve so the fuel is there when the options are called. The Commerce Commission authorised the arrangement because it coordinates competitors.
Swaption and cap compared
| Cap | Swaption | |
|---|---|---|
| Exercise | Automatic, in each period spot exceeds the strike | Holder elects in advance, for a block of time |
| Typical strike | High, for price spikes | Often high, for sustained dry periods |
| Seller’s need | Cover spike risk | Cover fuel and standby costs of thermal plant |
When a swaption is called, the seller usually has to generate or buy the power to back it. That links swaption strikes closely to the seller’s fuel cost, which brings us to the gas market (section 10) and spark and dark spreads.
Natural gas and the emsTradepoint market
Gas is New Zealand’s largest thermal fuel for electricity (about 8% of generation in 2025, against 3.5% from coal), but not the only one. Huntly’s three Rankine units can burn gas or coal, and when gas is short, as in winter 2024, they switch to coal, so in tight periods the fuel setting the price is often coal from the Huntly stockpile. Gas prices still feed straight into spark spreads, swaption strikes and the electricity forward curve, and gas supply decides how hard the coal backstop is worked. Most gas is sold under private supply agreements, so the one public price comes from emsTradepoint, the wholesale gas exchange.
What it is
Traditionally, producers sold gas to large users and retailers under bilateral supply agreements, usually for two to three years at a time, at prices that are never published. emsTradepoint started in 2013. It is an anonymous, centrally cleared exchange for physical gas, delivered through the transmission pipeline, and it is owned and operated by Transpower. It offers:
- Spot: day-to-day trading of gas for near-term delivery.
- Forwards: contracts listed on screen up to 24 months ahead, with published monthly and quarterly price indices.
- Options: exchange-traded gas options, first traded in 2025.
- Brokered trades: deals further out than 24 months can be negotiated through a broker, then cleared and settled through emsTradepoint. Both sides get central clearing instead of carrying each other’s credit risk.
Prices are quoted carbon-inclusive. At an NZU price of $57, about $3/GJ of a $20/GJ price is carbon (0.054208 t CO₂-e per GJ). Check whether a contract price you are comparing includes carbon too.
Why more users are turning to it
As supply tightens, producers are less willing to commit gas for the usual two to three year terms. More industrial users and retailers who cannot secure a traditional supply agreement now buy on emsTradepoint instead. In 2025 about 6% of the gas produced was traded on the exchange. That is still a small share, but it is the only transparent price and an increasingly important source of supply.
How trading works: no clearing price
The electricity spot market is a single auction: generators offer, the cheapest are dispatched, and everyone at a node is paid the same price for the trading period. emsTradepoint is a continuous market. A trade forms whenever a bid and an offer match, and its price and volume are fixed at that moment. Two trades for the same gas day can go through at different prices. The daily price emsTradepoint publishes is the volume-weighted average of the day’s trades (VWAP): it describes what happened, it is not what anyone pays.
| Electricity spot market | emsTradepoint gas | |
|---|---|---|
| How prices form | Auction each trading period, one clearing price per node | Continuous trading, each trade at its own price |
| What you pay | The clearing price for the period | The price of your own trade |
| Published price | Final price, which contracts settle against | Daily VWAP and price indices, for reference |
| Forward contracts | ASX futures and CFDs settle in cash against spot | Physical gas at the traded price, no cash settlement against spot |
| Getting out of a forward | Holds to expiry and settles itself, or close out on the ASX | Trade your way out: sell what you bought, or buy back what you sold |
An emsTradepoint forward is a commitment to deliver or take gas at the price you traded. If the price moves against you, nothing settles it for you. You bought 5,000 GJ for next month at $16/GJ and the price falls to $12/GJ: if you no longer need the gas, you sell it at $12 and lock in a $20,000 loss. If you keep it, you pay $16 for gas now worth $12. Either way, the position only closes when you trade it.
Gas options
A call option gives the buyer the right, but not the obligation, to buy gas at an agreed price (the strike). A put option gives the right to sell at the strike. The buyer pays a premium for that right, and the most they can lose is the premium.
- Gas users buy calls as insurance. A call caps the price for a set volume without locking in a full contract, and if spot stays low the user simply buys at spot.
- Producers and sellers buy puts to set a minimum price for gas they expect to sell.
- Option writers (the sellers) keep the premium in return for giving up the price moves beyond the strike.
The first exchange-traded gas option showed how this works in a tight market. It was executed in September 2025. Soon after, spot gas traded as high as $41/GJ, and the holder exercised the option to secure gas at the strike. Gas options work like the electricity caps and floors in section 08: a gas call alongside an electricity cap lets a gas-fired generator or large user hedge both the fuel and the power price.
Compared with buying the same volume at spot. Prices carbon-inclusive. Illustrative only.
Why gas moves electricity prices
New Zealand has no gas import terminal and very little storage, so every unit of gas used is produced here, and a fall in supply has to be met by using less. In a dry year generators need extra gas exactly when there is none to spare, and gas and electricity prices rise together. In the 2024 dry year spot gas reached $30–40/GJ and daily electricity prices passed $800/MWh. In summer it reverses: in late 2025 spot gas fell below $6/GJ. When gas runs short, Huntly switches to coal, so watch the coal stockpile alongside gas deliverability.
- Supply is falling faster than forecast. Proven and probable (2P) reserves fell 23% to 731 PJ at 1 January 2026, the lowest on record. Production in 2026 is expected to be about 85 PJ, down from 116 PJ in 2024.
- Big changes are close. The Māui field is expected to stop producing at the end of 2026. Methanex, the largest gas user, plans to idle its New Zealand plants from early 2027 and has sold most of its remaining gas contracts, including to Genesis Energy. More gas will go to generation, but there is less of it overall.
- LNG would set a ceiling. The Government has decided to build an LNG import terminal at Port Taranaki, aiming for 2027–28. A contract is still to be signed. Imported gas would cap dry-year gas prices at roughly the cost of a cargo. The forward curve has already responded: electricity prices for 2028 and 2029 fell by around $20/MWh after the February 2026 announcement.
Watch emsTradepoint spot and forward prices as a leading indicator for the electricity curve. Producer deliverability forecasts, field outages and the timing of Māui’s closure all move winter electricity prices. Gas price × heat rate sets the floor under spark spreads (section 11) and under the strikes of swaptions and caps. Figures here are as at November 2026.
Spark, dark and clean spreads
A spread is the gross margin a thermal plant earns from turning fuel into electricity. It tells a trader whether running the plant makes money at today’s prices.
- Spark spread: electricity price minus the cost of the gas burned.
- Dark spread: the same calculation for coal.
- Clean spread: also subtracts the carbon cost, measured in New Zealand Units (NZUs) under the ETS.
Heat rate is the GJ of fuel needed per MWh of electricity. Lower is more efficient. The emissions factor is tonnes of CO₂ per GJ of fuel. MBIE publishes an official emissions factor for each thermal generator. For example, emissions from gas turbines use a factor of 0.054208 tonnes CO₂-e per GJ of natural gas.
Worked example (illustrative numbers only)
| Item | Value |
|---|---|
| Electricity price | $200/MWh |
| Heat rate (efficient gas plant) | 7.5 GJ/MWh |
| Gas price | $15/GJ |
| Fuel cost (7.5 × $15) | $112.50/MWh |
| Carbon (7.5 GJ × 0.054208 t/GJ × $60/NZU) | $24.39/MWh |
| Clean spark spread | $63.11/MWh |
A positive spread means the plant should run. A negative spread means buying from the market is cheaper than generating.
Uses the gas emissions factor of 0.054208 t CO₂-e/GJ. Illustrative only.
Why New Zealand traders watch it
- Thermal plant sets the price in many trading periods, especially in dry years, so gas and coal costs flow straight into the forward curve.
- Tighter gas supply raises the floor under winter prices.
- Swaption and cap strikes are anchored to the seller’s spread. A seller will not sell cover below the cost of generating it.
- A tolling agreement, where you pay a plant owner to convert your fuel into power, is a way of buying a spark spread directly.
Financial transmission rights (FTRs)
An FTR pays the holder the price difference between two grid hubs. It hedges basis risk: the gap between the node a contract settles at and the node where you actually buy or sell.
An Auckland retailer hedges with a Benmore-referenced CFD. When North Island prices rise above Benmore, for example when HVDC transfer north is constrained, the retailer pays the higher Auckland spot price but the CFD only compensates at Benmore. That gap is unhedged.
How New Zealand FTRs work
- They are auctioned regularly by the FTR Manager between a set of major hubs, including Otahuhu, Haywards and Benmore.
- Obligation FTR: pays the price difference in the chosen direction, and costs the holder if it reverses. It is equivalent to a locational swap.
- Option FTR: pays only when the difference is in the holder’s favour. Less downside, higher auction price.
- They are funded from the transmission loss and constraint rentals that arise when prices differ across the grid.
An obligation FTR from Benmore to Otahuhu for 10 MW. In a trading period where Otahuhu is $220 and Benmore is $180, it pays $40/MWh × 10 MW × 0.5 hours = $200.
The Auckland retailer combines a Benmore CFD with a Benmore-to-Otahuhu FTR to create an effective Otahuhu hedge.
Weather derivatives
CFDs, futures and options fix what you are paid for each MWh. They do nothing if the MWh are not there. In New Zealand the weather decides much of the volume: rain and snowmelt fill the hydro lakes that supply more than half of the country’s electricity, wind output is usually lowest from April to July when demand is highest, and cold snaps push up winter demand. A weather derivative pays out on the weather itself.
How they work
- Index: a weather measurement at an agreed station over an agreed period, such as average wind speed from June to August.
- Strike: the index level where payments start, usually set below normal, like an insurance excess.
- Tick: the payment for each unit the index moves past the strike, for example $100,000 per 0.1 m/s.
- Cap and premium: a maximum payout, and the price paid upfront for the protection. Swaps, with no upfront premium, are also possible.
Which weather, and for whom
| Index | Typical user | What it protects |
|---|---|---|
| Rainfall or river inflows | Hydro generators | Lost output in a dry season |
| Wind speed | Wind farm owners, buyers of pay-as-produced PPAs | Lost output, or a shortfall in contracted volume, in a calm season |
| Temperature (heating degree days) | Retailers on fixed price variable volume contracts | Extra demand bought at high spot prices in a cold winter |
| Sunshine or solar irradiance | Solar farm owners | Lost output in a cloudy season |
Worked example: a wind farm’s winter
A 50 MW wind farm sells all its output under a pay-as-produced PPA at $110/MWh, so its price is fixed but its volume is not. In a normal winter the wind at the nearby weather station averages 8.0 m/s. For this farm, each 0.1 m/s change in the winter average changes output by about 1,000 MWh, worth $110,000. Real power curves are not straight lines, but this is close enough to show how the hedge works.
The owner buys a wind-speed option: it pays $100,000 for every 0.1 m/s the June to August average at the station falls below 7.6 m/s, up to $1.2m, for a premium of $180,000.
Without the weather hedge
With the weather hedge
Illustrative figures. Move “Farm vs station” to see basis risk: the hedge pays on the station’s wind, the farm earns on its own.
| Station wind | Revenue | Payout | Unhedged | Hedged |
|---|---|---|---|---|
| Normal: 8.0 m/s | $0 | $0 | $0 | −$180,000 |
| Calm: 7.0 m/s | −$1,100,000 | +$600,000 | −$1,100,000 | −$680,000 |
| Very calm: 6.4 m/s | −$1,760,000 | +$1,200,000 | −$1,760,000 | −$740,000 |
| Windy: 8.6 m/s | +$660,000 | $0 | +$660,000 | +$480,000 |
All figures are compared with a normal winter, with the farm’s wind the same as the station’s. “Hedged” includes the $180,000 premium. The hedge costs $180,000 in a normal or windy winter, roughly halves the loss in a calm one, and caps the damage in a very calm one. Together with the PPA, which fixes the price, it brings the farm’s winter revenue much closer to certain.
Why traders like them: they are not linked to the market
- They hedge the cause, not the symptom. A calm winter is a volume problem. A price hedge can make it worse: a generator that sold forward and cannot produce must buy back at spot. A weather hedge pays because the wind did not blow, whatever prices did.
- The other side is not caught in the same squeeze. In a dry year everyone in the power market wants price cover at once, and futures prices jump. Weather risk is mostly taken by insurers, reinsurers and investors who hold weather risk around the world, so a New Zealand dry spell is one small part of their book. Cover is still available when the local market is stressed.
- Settlement is clean. A station reading cannot be moved by a large trade, a plant outage or anyone’s offers, so there is little to dispute.
- No margin calls. A weather option is usually paid for once, upfront, unlike futures, which can demand cash every day in a dry spell.
- Diversification. Weather is largely independent of financial markets, which attracts investors and keeps capacity in the market.
The limits
- Basis risk. The station is not the farm or the catchment. Choose a station close to the site with a strong record of matching its output.
- A small, tailored market. In New Zealand these are arranged privately with insurers, reinsurers and banks, not traded on an exchange. Each one is bespoke, so pricing is less transparent and exiting early is hard.
- Data and a changing climate. Pricing relies on long, clean weather records. Climate change is shifting rainfall patterns and wind speeds, so history is a less reliable guide than it was.
- Insurance or derivative. Some are written as insurance contracts rather than derivatives. That changes the legal, tax and accounting treatment, so get advice on the structure.
- Credit. The premium is paid upfront, but the payout depends on the seller being able to pay after a bad season.
How REGOs and RECs interface with each product
Certificates and REGOs carry the renewable claim. Contracts carry the price. The two are separate, and a certificate moves with a contract only when the contract says so (bundled). The financial-only products in this primer carry no certificates, so a buyer who wants a renewable claim must source certificates alongside the hedge.
Three principles matter:
- Electrons are not labelled. In a pooled market, the certificate is the only thing that proves renewable supply. No certificate, no claim.
- Bundled and unbundled. A PPA can bundle certificates with the price hedge. Futures, options, FTRs and weather derivatives never do. Certificates are bought separately (unbundled).
- Granularity matters. A volume-based certificate proves annual MWh. A granular, half-hourly certificate proves the renewable MWh were generated in the same trading period the buyer consumed. That is the test applied by temporal matching standards such as EnergyTag and the GHG Protocol Scope 2 revision.
REGOs and RECs in New Zealand
| Granular REGO | RECs | |
|---|---|---|
| Time basis | Half-hourly, matched to each trading period | Volume-based (1 MWh), typically matched annually |
| Data source | Revenue meter data, including the EA consumer meter data service live from 30 October 2026 | Generation data reported to the issuer |
| Issuer or platform | Proposed: granular certificate platforms | BraveTrace (NZECS) and Transpower (I-REC) |
| Supports 24/7 claims | Yes | No |
Product by product
| Product | Certificates attached? | How certificates interface | Watch out for |
|---|---|---|---|
| Sleeved PPA | Usually bundled | Generator transfers certificates for the contracted volume, via the retailer or directly to the buyer | The contract must name who holds and retires them, or the retailer may claim them |
| Virtual PPA (CFD) | Bundled by contract | Price settles financially. Certificates transfer separately for each MWh generated | The claim rests entirely on the certificates. Granular REGOs show the half-hourly fit with the buyer’s load |
| OTC CFD or swap | No (default) | A certificate leg can be added at a premium (a green swap) | Baseload hedges usually come from a mixed portfolio, so there is no renewable claim without that leg |
| ASX futures | Never | Buy unbundled certificates separately | Exchange products are price-only by design |
| Caps, floors, collars | Never | Buy unbundled certificates separately | Option payouts say nothing about how the power was generated |
| Swaptions and dry-year cover | Never | Buy unbundled certificates separately | Usually backed by thermal plant. In dry periods renewable supply is scarcest, so granular REGOs are most valuable |
| Spark and dark spreads, tolling | Never | Thermal generation creates no REGOs | The carbon cost here is NZUs, an emissions liability, not a renewable certificate |
| FTRs | Never | No direct link | Some standards require generation and load to be in the same grid. New Zealand’s single grid generally meets this |
| Weather derivatives | Never | No direct link. They pay on a weather index, not on MWh generated | A payout replaces lost revenue, not lost certificates. In a calm or dry season the plant issues fewer REGOs, so a buyer relying on them must source replacements, often when renewable supply is scarcest. Size the tick to cover the certificate value too if that matters |
| Unbundled certificate purchase | The product itself | Buyer purchases REGOs or RECs with no price hedge attached | Without a matching price hedge, the buyer’s energy cost is still exposed to spot |
The certificate value sits on top of the electricity price. A renewable PPA strike typically includes a certificate premium. The gap between a bundled PPA price and an equivalent baseload swap is a rough guide to what the market pays for the renewable claim.
Risks that hedges do not remove
A hedge that looks complete on paper can still lose money. These are the gaps to check on every deal.
| Risk | What goes wrong | Usual mitigant |
|---|---|---|
| Basis (location) | The contract node price differs from your own node | FTRs |
| Shape | Contract volume does not match when you produce or consume (solar at midday, demand in the evening peak) | Shaped or peak products, storage, granular REGO matching |
| Volume | Actual load or generation differs from the hedged amount | Load-following contracts, conservative hedge ratios, weather derivatives (section 13) |
| Credit | A counterparty cannot pay large settlements during a price spike | Credit limits, collateral, exchange clearing |
| Liquidity | You cannot trade out of a position at a fair price | Use standard ASX products where possible |
| Regulatory | Market rule or code changes alter how contracts settle | Change-in-law clauses |
Shape risk matters most for renewable PPAs. A pay-as-produced CFD hedges the MWh the plant generated, not the MWh the buyer used in the same half-hour. Temporal matching and granular certificates make that gap visible.
Volume risk that comes from the weather, such as a dry year or a calm winter, can be hedged directly with weather derivatives. See section 13.
Test yourself
Twenty-seven quick questions on everything in the primer: multiple choice, a few sliders and a chart. No prizes, and only a little judgement.
Each answer comes with a short explanation and a link back to the right section. Sliders give half a point for a near miss.
For fun and learning only. Figures are illustrative and match the examples in this primer. Your score stays in your browser.
Glossary
- Baseload
- Flat volume every trading period, around the clock
- Basis risk
- Price gap between the contract node and your own node
- Bid and offer
- The prices at which someone will buy (bid) and sell (offer). The offer is also called the ask
- Bid-ask spread
- The gap between the best bid and the best offer. A narrow spread makes trading cheaper
- Call option
- The right, not the obligation, to buy at the strike. Gas users buy calls to cap their fuel cost (section 10)
- Cap
- Option paying the buyer when spot exceeds the strike
- Carbon-inclusive price
- A gas price that includes the ETS carbon cost, as quoted on emsTradepoint. About $3/GJ at an NZU price of $57
- CFD, swap or hedge
- Contract settling the difference between strike and spot
- Clean spread
- Spark or dark spread after carbon cost
- Collar
- Bought cap plus sold floor, holding price within a band
- Continuous trading
- Trades form whenever a bid and offer match, each at its own price, with no single clearing price. How emsTradepoint works
- Dark spread
- Electricity price minus coal fuel cost
- Dispatch price
- A price set each time the system operator issues dispatch instructions, roughly every five minutes, at every node
- EFP
- Exchange for physical: swapping an OTC position for the matching futures or options position
- emsTradepoint
- New Zealand’s wholesale exchange for physical gas and NZUs, owned by Transpower. Spot, forwards up to 24 months on screen, and options
- Final price
- The confirmed half-hour spot price that the market and contracts settle on
- Firming option
- A long-dated option (usually a swaption) that pays a thermal plant owner to keep capacity and fuel ready for dry years or gas shortfalls (sections 02 and 09)
- Floor
- Option paying the seller when spot falls below the strike
- Forward curve
- Current market prices for each future delivery period
- FPVV
- Fixed price variable volume: retail supply at fixed rates on whatever the customer uses
- FTR
- Financial Transmission Right, paying the price difference between two hubs
- Generation following
- PPA volume that tracks what the plant generates (pay-as-produced)
- Gentailer
- A company that is both generator and retailer
- GJ and PJ
- Gigajoule and petajoule, units of gas energy. 1 PJ = 1 million GJ. New Zealand used about 100 PJ of gas a year in the mid-2020s
- Heat rate
- GJ of fuel needed per MWh generated
- Heating degree days
- A measure of how cold a period was: each day’s shortfall of average temperature below 18°C, added up
- Initial margin
- Cash or collateral posted with the clearing house when a futures position is opened
- Instantaneous reserve
- Generation or interruptible load held ready to cover the sudden loss of a large generator or transmission link
- Interim price
- The time-weighted average of the dispatch prices, published as soon as the trading period ends
- Liquidity
- How easily a meaningful volume can be traded quickly at a fair price
- LNG
- Liquefied natural gas, shipped by sea. An import terminal would let New Zealand top up domestic gas in dry years
- Load following
- Contract volume that tracks what the buyer consumes
- Mark-to-market
- Revaluing a contract against the current forward curve
- Market depth
- How much volume is available at or near the best bid and offer
- Market maker
- A participant that posts buy and sell prices at the same time so others can trade. In New Zealand, a Code requirement on the largest gentailers (section 07)
- Node
- Grid location with its own spot price
- NZU
- New Zealand Unit under the Emissions Trading Scheme (1 tonne CO₂-e)
- Pay-as-produced
- Volume equals a specific plant’s actual output
- PPA
- Long-term agreement to buy a generator’s output at a set price
- Premium
- Up-front price paid for an option
- Put option
- The right, not the obligation, to sell at the strike. Producers buy puts to set a minimum price
- Real-time pricing
- The way New Zealand has set spot prices since November 2022: from live dispatch prices, published at the end of each trading period (section 03)
- REGO
- Renewable Energy Guarantee of Origin certificate
- Reserves (2P)
- Proven plus probable gas reserves: the official estimate of gas that can be produced commercially
- Scarcity pricing
- Preset high prices that apply automatically when there is not enough energy or reserve
- Sleeved PPA
- PPA passed through a retailer to the end buyer
- Spark spread
- Electricity price minus gas fuel cost
- Spot pass-through
- Retail supply charged at the spot price plus a margin
- Strike
- The fixed price in a CFD or option
- Super-peak contract
- A standardised CFD covering the morning (7:00 to 10:30 am) and evening (5:00 to 9:00 pm) peaks every day
- Swaption
- Option to enter a swap for a future period
- Tolling
- Paying a plant owner to convert your fuel into electricity
- Trade your way out
- Closing a physical forward position by making the opposite trade at the current price, since nothing settles it automatically
- Trading period
- One half-hour, the New Zealand market’s pricing interval
- Two-way price
- A bid and an offer quoted at the same time
- Variation margin
- Daily cash payments that settle each futures position’s gains and losses
- VWAP
- Volume-weighted average price: the average of a day’s trades, weighted by volume. A reference price, not a settlement price
- Water value
- The value a hydro generator places on stored water, based on what it may be worth later
- Weather derivative